With 100% effort to customer satisfactionGLOBAL BUSINESS NO.1 BU GIL SPRING CO., LTD.

HOME > About Product > Hot Wound Coil Spring

Hot Wound Coil Spring

Characteristic

  • Springs are molded in the hot state using materials with a diameter of 10mm or above
  • Materials have rectangular and circular cross-section, etc.
  • Cylindrical shape is the most common. Cone-shaped or hourglass-shaped springs for special purposes are also available.

Production video

Application

  • Cars
  • Railroad Cars
  • Construction Equipment
  • Marine Engine Valves
  • Anti-vibration Devices
  • Pipe Hanger
  • Industrial Machinery
  • Nuclear Power Plants

Material

KS(Korea) JIS(Japan) SAE(USA)
SPS 5~5A SUP 9~9A 5155~5160
SPS 6 SUP 10 -
SPS 7 SUP 11A 51B60
SPS 8 SUP 12 9254

For the design and materials of springs, please consult with our technical sta.

Order Specification

(a)Butt end(not ground)
(b)Butt end(ground)
(c)Butt end(tapered)
(d)Bevelling(grind)
(e)Bevelling(not ground)
(f)Tangent Tail End

Matters to record when placing an order

Standing Item Labeling Requirements Remark
1 Material   Calculation based on manufacturer standards unless otherwise specied
2 Wire Dia (d) mm  
3 Mean Dia (Dm) mm Selection between DE or DI
4 Out Dia(Do) mm DE tolerance management according to assembly conditions
5 Inside Dia(Di) mm DE tolerance management according to assembly conditions
6 Active Turn(Na) Coil As per the design standard of manufacturer
7 Total Turn(Nt) Coil As per the design standard of manufacturer
8 Direction of wind Left · Right As per client's request
9 Free Height(Ho) mm Spring for load management and reference to
10 Spring Rate(K) kgf / mm  
11 Load Condition mm, kgf As per client's request
12 Type od Ends Butt end, Taper As per client's request
13 Hardness HB 388 ~ 514 Specied by manufacturer
14 Carry Out Shot-peening  
15 Finish Enamel, Power, Phosphate As per client’s request
16 Application and Working Conditions Labelling requirement by client Application, Working Temperature, Humidity and Working Environment
17 Other Standards KS B2402, KS B2403